The Yokogawa EJA110E high-performance differential pressure transmitter is one of the most trusted DP transmitters in industrial process control today. Built on single-crystal silicon resonant sensor technology, it measures differential pressure, flow, level, density, and static pressure across liquids, gases, and vapors. It outputs a standard 4-20mA DC signal and supports HART and FOUNDATION Fieldbus communication. With ±0.055% reference accuracy, a 100:1 range ratio, and SIL2/SIL3 safety certifications, the EJA110E meets the strict demands of petrochemical, power, and oil and gas applications.
The EJA110E uses Yokogawa's DPharp digital sensor technology, which uses silicon elements that vibrate to turn applied pressure into frequency signals. Readings from this method are faster and more accurate than readings from standard strain gages. Even when the process pressure stays the same, the sensor keeps sending frequency data, so if there is a problem with the hardware, an alert goes off right away. This design for live tracking helps operations teams quickly tell the difference between real process events and problems with the equipment.
| Parameter | Main Variable (DP) | Auxiliary Variable (SP) |
|---|---|---|
| Reference Accuracy | ±0.055% | ±0.5% |
| Response Time | 90 ms | 360 ms |
| Long-term Stability | ±0.1% URL / 10 years | — |
| Overpressure Effect | ±0.03% URL | — |
| Range Ratio | 100:1 | — |
The parameters are the main variable (DP) and the auxiliary variable (SP). The accuracy of the reference is ±0.055% for DP and ±0.5% for SP. The response time is 90 ms for DP and 360 ms for SP. The long-term stability is ±0.1% URL/10 years for DP and 0.03% URL for SP. The overpressure effect is 0.03% URL for DP and 0.03% for SP. The range ratio is 100:1.
The most common sources of measurement error can be avoided with proper installation. When used with liquids, mounting direction can change the zero-point shift. To take static head effects into account, engineers should do a zero calibration after installation. For HART-enabled units, regular parameter changes can be made without having to be on-site using a mobile communicator or asset management software for online setup. Traceability to national measurement standards is maintained by revalidating calibration every 12 months.
Each model in Yokogawa's own line of products has a specific job to do. The EJA120E works best with low differential pressure ranges, which are common in monitoring draft pressure and filters. The EJA530A is designed to measure gage pressure in situations with higher pressures. The Yokogawa EJA110E high-performance differential pressure transmitter can measure differential pressure over the widest range of the three. This makes it the standard choice for measuring flow and level in process industries. Being able to turn down 100 times means that one unit can handle a lot of different processes without needing to be replaced.
The Emerson Rosemount 3051 is a popular competitor that is known for integrating well with Emerson DeltaV systems. In the European process areas, the Siemens SITRANS P DS III works well. The EJA110E's ±0.055% precision and ±0.1% URL 10-year stability specifications are the best in the business and can't be matched by either of its competitors across the entire measurement range. When long periods of time between calibrations are important, like on offshore platforms or remote pipeline stations, the EJA110E's track record of steadiness gives procurement teams a clear cost edge over the lifecycle of the instrument.
Field data from petrochemical and water treatment operators confirms that the EJA110E usually needs fewer service interventions than alternatives of the same price. The dual-seal construction that is ANSI/ISA 12.27.01-certified and the wetted 316L stainless steel parts make corrosion-related failures less likely. These things lower the total cost of ownership, which is something that procurement managers are looking at more and more along with the buy price when they are choosing DP transmitter providers.
When you buy from an authorized dealer, you avoid getting fake goods and can get the full Yokogawa factory guarantee. The Shaanxi Honglixing Electronic Technology Co., Ltd. (HLX) is a licensed distributor that sells genuine Yokogawa instruments to companies in the chemical, power, petrochemical, and oil industries. From placing an order to making sure it gets delivered, our procurement team handles competitive pricing, tracking wait times, and helping with paperwork.
When they are in stock at a dealer, standard EJA110E versions usually ship within two to four weeks. When you place a bulk order through HLX, you can get a group price, which lowers the cost per unit by a large amount for projects that need more than one transmitter. We also work with OEMs to make custom configurations, co-branded documentation, and priority allocation agreements for buyers who buy a lot of products. With these choices, business development managers and procurement directors can set up supply channels that can grow without having to worry about supply interruptions.
Every EJA110E that HLX sells comes with the full Yokogawa manufacturer warranty. Our after-sales tech team has more than ten years of experience in the field and can help with installation, commissioning, calibration, and problem analysis. We answer technical questions within one business day and provide help across regions for clients with plants in different places.
The EJA110E works within the accuracy ranges that were published by being inspected once a year. Some important jobs are checking the impulse line for leaks or blockages, looking for early signs of rust on the process flange seals, and comparing the output signal to a known standard. The way to clean sensors depends on the type of process fluid. For example, liquid applications may need to be purged every so often, while gas service units need to have their moisture drains checked.
The Yokogawa EJA110E high-performance differential pressure transmitter can check for and fix most hardware problems on its own, before they affect the quality of process data. If the output signal changes without warning, the first thing you should do is check the 4-20mA loop for problems with the wires or the power source. Signal errors that don't go away after loop checks are usually a sign of a damaged sensor module. Yokogawa's field service team can confirm this with diagnostic tools they bring to the site. The original Yokogawa EJA110E technical datasheet (document GS 01C25B01-01EN) has fault code tables with thorough information and suggested ways to fix them.
Some problems, like internal diaphragm damage from very high pressures, need to be fixed at the factory level or the module needs to be replaced. When new parts or specialized techs are needed, HLX's technical team directs the issue to Yokogawa's service network and gives advice on how to escalate the problem. Customers who have maintenance contracts get priority scheduling, which cuts down on unplanned downtime during busy production times.
Yokogawa has factories that are certified to meet the requirements of ISO 9001 and IEC 61508. TÜV Rheinland and EXIDA approvals show that SIL2 single-use and SIL3 redundant safety standards are met by products bought through approved outlets like HLX. For project engineering packages sent to regulatory bodies in the oil and gas, power, and chemical sectors, this compliance paperwork is a must.
Yokogawa spends a lot of money on research and development every year to improve sensor technology and integrate digital systems. The EJA-E series, which includes the EJA110E, is the result of years of small improvements in engineering that have made calibration intervals longer and sensor lifespans better than in previous generations. When buyers work with Yokogawa through authorized distributors, they get early access to firmware updates, product updates, and application support documentation.
Plant instrumentation managers at several power generation and refinery sites have reported calibration intervals longer than 18 months without drifting beyond what is acceptable. This is because the EJA110E is designed to be stable over a long period of time. These performance records cut down on the cost of maintenance work and help make sure that internal quality checks are followed.
The Yokogawa EJA110E high-performance differential pressure transmitter stands out as a reliable DP transmitter that is well-designed for harsh industrial settings. It is a good buy for measuring flow, level, and pressure in many fields thanks to its DPharp sensor technology, safety ratings, and long-lasting calibration stability. When procurement teams choose an authorized supply source, they get real goods, full warranty coverage, and technical help that keeps instruments working well over time. The EJA110E gives you accurate measurements that your process control system can count on, whether you are in charge of a single spot or several plants.
The EJA110E can measure differential pressure with a reference accuracy of ±0.055%. There is an alternative accuracy setting of ±0.04% that can be used for tasks that need to be more precise, like custody transfer metering.
Yes. Most of the DCS and SCADA systems used in process industries today, like the Yokogawa CENTUM VP, Emerson DeltaV, and Siemens PCS 7, can talk to the EJA110E using the HART and FOUNDATION Fieldbus communication protocols.
The EJA110E is safe and meets the standards set by IEC 61508:2010 and IEC 61511:2004. SIL2 standards can be met by single-unit setups. SIL3 is reached with redundant configurations. Third-party certification comes from TÜV Rheinland and EXIDA.
HLX does offer volume discounts for large orders and is open to OEM partnership agreements. Email our team at sales01@hlx8.com to get a quote and shipping plan that are tailored to your project.
All of the EJA110E units that Shaanxi Honglixing Electronic Technology Co., Ltd. sells come with the full Yokogawa factory guarantee. During the coverage period, our after-sales tech team takes care of warranty repairs or replacements.
The Yokogawa EJA110E high-performance differential pressure transmitter is sold by HLX, which offers reasonable prices, full after-sales technical support, and certification from the original maker. Our expert team can help you choose the right transmitter setup for your process because we are an official Yokogawa dealer. For a personalized quote, please email us at sales01@hlx8.com. Bulk orders and OEM pricing options are open to people who qualify.
1. Yokogawa Electric Corporation. EJA110E Differential Pressure Transmitter Technical Datasheet GS 01C25B01-01EN. Yokogawa Electric Corporation, 2022.
2. International Electrotechnical Commission. IEC 61508: Functional Safety of Electrical/Electronic/Programmable Electronic Safety-related Systems. IEC, 2010.
3. International Electrotechnical Commission. IEC 61511: Functional Safety — Safety Instrumented Systems for the Process Industry Sector. IEC, 2004.
4. ISA — International Society of Automation. ANSI/ISA 12.27.01: Requirements for Process Sealing Between Electrical Systems and Flammable or Combustible Process Fluids. ISA, 2011.
5. Control Engineering Magazine. "Differential Pressure Transmitter Selection and Performance Benchmarking in Process Industries." Control Engineering, 2021.
6. Measurement + Control Journal. "Long-Term Stability and Calibration Interval Analysis for Silicon Resonant Sensor Transmitters." Institute of Measurement and Control, 2020.
Our customers’ satisfaction speaks for our quality — contact us to experience the same reliable service.