The yokogawa EJA110E high-performance differential pressure transmitter works with an orifice plate when the whole installation is engineered correctly. The orifice restricts flow and creates a pressure drop. The transmitter measures the difference between the upstream and downstream pressures and sends a 4–20 mA DC signal to your control system. Compatibility depends on more than the transmitter. Orifice sizing, fluid properties, pressure, temperature, impulse piping, manifold, protocol, and wetted materials all matter. I wrote this guide to help engineers and buyers check each point before ordering.
When fitted in a pipe, an orifice plate is a thin plate that has a hole that has been cut with great precision. The velocity of the fluid increases as it travels through the hole, but the pressure decreases. The difference in pressure increases as the flow rate increases, and the flow rate is generally equal to the square root of the difference in pressure. Orifice plate geometry and installation restrictions are aspects that are covered by ISO 5167-2. The EJA110E is positioned next to the pipe and uses impulse lines to establish connections with the taps located both upstream and downstream. The minor pressure differential is detected by its single-crystal silicon resonance sensor, which then translates the information into a DC output ranging from 4 to 20 milliamperes. As the signal is a representation of pressure rather than flow, the control system is responsible for making the conversion.
The question of which gadget calculates flow is often asked by purchasers. A differential pressure measurement is taken by the transmitter. For the purpose of converting that pressure into flow, a PLC, DCS, or flow computer will often use the square-root function in conjunction with the process data. Rather than that, the output of the transmitter is set to square-root mode by certain loops. Please choose just one place. In the event that the control system does the square root extraction again after the transmitter has already done so, the flow measurement will be inaccurate, particularly when the flow is low. During the commissioning process, it is recommended that the option be written down on the loop sheet and then confirmed. The density, pressure, and temperature adjustments for gas and steam may also be accomplished with the help of a flow computer.
Check the following six elements before you decide to accept the pairing: the calibrated span in comparison to the predicted differential pressure, the maximum static pressure, the vacuum exposure, the ambient temperature and the process temperature, the process connections, and the wetted materials. The Yokogawa EJA110E High-performance Differential Pressure Transmitter is capable of measuring static pressure as an auxiliary variable, which provides you with additional information on the specific process. Make sure that the design of the manifold and the materials it is made of are appropriate for the fluid, since even a proper transmitter on a manifold that is not well selected will still provide bad results. Make sure that each item is matched to the full model code as well as the most recent paperwork from the manufacturer, and not just to a short product name.
There are four distinct values that make up the sensor: the range, the calibrated span, the operating differential pressure, and the maximum working pressure. In terms of sensor range, the capsule is capable of handling. The range that you provide to the 4–20 mA output is referred to as the calibrated span. The operating differential pressure is the pressure that is produced by the orifice when it is deployed. The EJA110E has a range ratio of 100:1, which allows a single model to accommodate a wide variety of spans. Due to the fact that flow is proportional to the square root of pressure, a transformation of 10:1 in flow requires a change in differential pressure of 100:1. In the initial step of the process, I examine the minimal flow scenario, and then I choose the narrowest span that accounts for the maximum flow with margin.
According to the EJA110E, the reference accuracy for differential pressure is ±0.055%, while the reference accuracy for static pressure is ±0.5%. Over a period of ten years, the long-term stability amounts to ±0.1% URL, whereas the overpressure impact amounts to ±0.03% URL. When it comes to differential pressure, the response time is 90 milliseconds, whereas when it comes to static pressure, it is 360 milliseconds. The transmitter is the only thing that these numbers describe. Additionally, the accuracy of your loop is dependent on the uncertainty of the orifice, impulse lines, the quality of the installation, and temperature. The frequency of recalibration visits and drift are both reduced by a steady transmitter; nevertheless, it is unable to repair a worn orifice edge or a clogged tap. The datasheet should be considered one of the inputs to the overall flow uncertainty.
The yokogawa EJA110E high-performance differential pressure transmitter sends a 4–20 mA DC signal. Depending on the model code, options such as HART or FOUNDATION Fieldbus may be available, so confirm the protocol before you order. TÜV Rheinland and Exida have certified the transmitter's performance. It meets the IEC 61508 and IEC 61511 functional safety standards. A single unit satisfies SIL2 requirements, and redundant configurations reach SIL3. Check hazardous-area approvals, materials, temperature limits, and process connections against the full model code, since the code defines exactly what ships.
This is where you should begin: with the orifice data, which includes the pipe size, bore diameter, beta ratio, plate material, flange rating, and design standard. It is common practice to use AGA Report No. 3 as the standard for natural gas. After that, make a note of the fluid phase, density, viscosity, compressibility, and the normal flow range that is anticipated. The differential pressure that the transmitter will perceive is determined by these particulars. It is possible for the predicted flow to be shifted even when the transmitter is reading flawlessly if the beta ratio or density value is incorrect. The orifice size sheet is something that I ask purchasers to supply together with the request since it allows us to validate the span and the materials in a single assessment.
In order to assess whether or not a good transmitter provides a decent reading, impulse piping is used. In liquid service, slope the lines so that gas may escape, and in gas service, slope the lines so that condensate can drain. Install vents and drains in areas where liquids might potentially get trapped. When there is a possibility of freezing or condensation, the lines should be insulated or heat traced. Condensate pots should be used for steaming so that both legs maintain the same amount of liquid. Due to the fact that it maintains the same pressure as the pipe, it is important to choose a manifold that has pressure and temperature specifications that correspond to the process. In addition, latency and disparities between the high and low sides are reduced when short lines of identical length are used.
Check the power and load resistance of the loop, use shielded cable with the appropriate grounding, and make sure the loop is wired with the right polarity. Put up barriers in areas where the laws for hazardous areas necessitate them. The next step in the commissioning process is to isolate the transmitter, check for leaks, vent or drain securely, open the equalising valve, adjust zero, simulate pressure, and verify the output at the PLC or DCS. It is common for symptoms to indicate obvious reasons. Excessive amounts of air in liquid lines or condensation in gas lines are often the cause of unstable readings. An isolation valve that is closed or a wiring failure might be the cause of a reading of 0 degrees. Typically, a reversed signal indicates that the high and low connections have been switched.
Flow, level, density, and pressure are all components that are measured by the EJA110E for liquids, gases, and vapours. In conjunction with orifice plates, it is used for the purpose of providing steam lines in power stations, pipeline flow in petrochemical facilities, cooling water, and natural gas circulation. Both insulation and condensate pots are required for steam. Density, compressibility, and hazardous-area tests are required for gas and natural gas, and flow computers are often used for these checks. Solids and caustic media need special consideration when it comes to liquid service. Tank level and filter differential pressure are both covered by the same transmitter platform in water treatment, provided it is designed appropriately. This allows facilities to keep fewer replacement models.
A complete request prevents wrong shipments. Send the yokogawa EJA110E high-performance differential pressure transmitter model code or nameplate photo, fluid, minimum and maximum flow, pressure, temperature, differential pressure range, orifice data, process connection, communication protocol, hazardous-area certification, materials, quantity, and destination. Ask the supplier to confirm authenticity, calibration documents, approvals, warranty, stock, and lead time in writing. HART suits many existing 4–20 mA plants, while FOUNDATION Fieldbus fits sites built around fieldbus diagnostics and asset management. Remote seals apply when the process fluid is hot, viscous, or corrosive.
I do not assert that a single brand is victorious in every circumstance. Make a comparison between the differential pressure range, the static pressure rating, the accuracy, the communication, the diagnostics, the approvals, the configuration tools, and the spare-parts packages. ABB, Rosemount, and Yokogawa EJA120E transmitters are examples of typical options. The choice of transmitter is often determined more by the control system that is installed and the service coverage than by the size of the transmitter. It is also important to determine if an orifice plate is the appropriate principal element. It is possible that magnetic, vortex, Coriolis, or ultrasonic meters will suit better in situations when there is a problem with pressure loss, turndown, fluid condition, or short straight pipe runs. By doing an engineering assessment at this time, expensive rework may be avoided.
Utilise a pressure source that can be traced. Put the transmitter in isolation, equalise it, and check that it is zero. Apply test points that are growing and decreasing, record the values as they were discovered and as they were left, and then compare these values to your tolerance. Prior to making any adjustments, it is important to first distinguish between zero error, span error, linearity, hysteresis, and process-induced error. It is possible that a shifted reading is caused by a clogged tap rather than the sensor; however, altering the transmitter would result in the true issue being concealed. In order to establish calibration intervals, the ten-year stability value of ±0.1% for the URL is helpful. However, the final schedule is determined by the processes and risk level of your site.
If a reading seems to be incorrect, the procedure should be checked first. Check the locations of the manifold valves, as well as any leaks, obstructions, and the orientation of the transmitter. The square-root setting, the wiring, and the DCS scaling should all be verified, and the local display should be compared to the value that is shown on the control system. The frequency data is continually sent by the DPharp sensor, and the Back-Check self-diagnosis feature assists in distinguishing between changes in the process and issues with the equipment. Additionally, technicians are able to alter settings without having to go to the field thanks to remote settings. It is important to maintain extra gaskets, fittings, manifolds, and mounting hardware ready for maintenance procedures. Keep track of the calibration history, as well as the serial numbers and model codes.
Before placing an order, you need to be sure that you have completed these three categories of checks:
The yokogawa EJA110E high-performance differential pressure transmitter measures the differential pressure an orifice plate creates, while the PLC, DCS, or flow computer usually converts that pressure into flow. Square-root extraction should happen in one place only. Its 100:1 range ratio, ±0.055% accuracy, and ±0.1% URL ten-year stability support orifice-plate loops. The loop result still depends on orifice data, fluid properties, impulse lines, manifolds, wiring, and protocol choice. A complete model code and application data prevent most selection errors. Calibration records and structured troubleshooting keep the loop accurate over time. Alternative transmitters and other flow technologies suit some conditions better, so the final choice should follow the technical, control-system, and procurement reviews.
Yes, if the range, connections, materials, impulse system, approvals, and control architecture match the application.
It measures differential pressure. Flow calculation and square-root extraction may occur in the transmitter or in the PLC, DCS, or flow computer, but not in both.
Yes, with proper impulse piping. Use condensate pots, keep both legs at equal levels, and insulate the lines.
The standard output is 4–20 mA DC. Confirm HART or FOUNDATION Fieldbus availability in the complete model code before ordering.
HLX, Shaanxi Honglixing Electronic Technology Co., Ltd., is an authorized Yokogawa distributor and a dependable supplier of the yokogawa EJA110E high-performance differential pressure transmitter. Email your model code, nameplate photo, or orifice data to sales01@hlx8.com. Our engineers will check compatibility, stock, lead time, and warranty terms before quoting. We supply original products with fast delivery and technical support.
1. ISO 5167-2: Measurement of Fluid Flow by Means of Pressure Differential Devices, Orifice Plates, 2003
2. AGA Report No. 3: Orifice Metering of Natural Gas and Other Related Hydrocarbon Fluids, 2000
3. Instrument Engineers' Handbook, Volume 1: Process Measurement and Analysis, 2003
4. Flow Measurement Engineering Handbook, 1996
5. Industrial Flow Measurement, 2005
6. IEC 61508: Functional Safety of Electrical/Electronic/Programmable Electronic Safety-Related Systems, 2010