Can Yokogawa EJA110E Measure Liquid Level in Closed Tanks?

share:

The yokogawa EJA110E high-performance differential pressure transmitter can measure liquid level in closed or pressurized tanks when you install and configure it as a differential pressure (DP) level transmitter. It does not read height directly. Instead, it compares the pressure at the bottom of the tank with the pressure in the vapor space above the liquid, so tank pressure cancels out and only the liquid column remains. The EJA110E converts that difference into a 4–20 mA DC signal. In this guide, I explain how the method works, which specifications matter, and how to avoid common errors. I also share what to check before you buy.

How the Yokogawa EJA110E Measures Liquid Level in a Closed Tank

Why Closed Tanks Need Differential Pressure

A gauge pressure sensor at the bottom of an open tank works fine because the liquid's top is at normal air pressure. When the tank is closed, the scene changes. Vapor or blanket-gas pressure pushes on both the liquid and the sensor, so the number that comes up is a mix of the weight of the liquid and the pressure in the vessel. This issue can be fixed with a DP transmitter. The side with high pressure is hooked up to the lower nozzle, and the side with low pressure is hooked up to the hollow space. The pressure in the vessel reaches both sides and cancels each other out, so the output moves with the liquid head. This job is a good fit for the Yokogawa EJA110E high-performance differential pressure transmitter, which checks the flow, level, density, and pressure of gases, liquids, and vapors.

The Hydrostatic Pressure Principle

The liquid head is equal to the density times the height times the gravity. Fresh water makes about 0.433 psi per foot, which is about 12 inches of water column per foot in US units. As a result, a 10-foot water level makes 4.33 psi. A liquid with a specific gravity of 0.8 only makes 80% of that, or about 96 inches of water column. The first thing I always ask buyers is the density. Your control system takes the pressure from the transmitter and turns it into level. The level reading changes even though the real height hasn't changed when the density changes because of weather or composition.

Wet-Leg and Dry-Leg Installation

The low-pressure impulse line stays empty and open to the vapor space when there is a dry leg between them. It works when the vapor won't cool down. If condensation builds up, it adds hidden head pressure, which makes the reading change. With a wet leg, a reference liquid is added to the low-pressure line. This works well for collecting vapors like steam. You set a negative lower range number and keep the leg height and fluid density fixed. This way, the filled leg always puts pressure on the low side. The reading is off because of trapped gas, evaporation, or the wrong leg height. Think about the leg type before you order because it changes the length you figure out.

Yokogawa EJA110E Specifications That Matter for Level Measurement

Measurement Range and Turndown

With a 100:1 range ratio, the yokogawa EJA110E high-performance differential pressure transmitter, a single transmitter type can cover a lot of ground. First, figure out your span by adding up the density, the change in level, and any wet-leg offset. Think about a 10-foot tank that has a liquid in it that has a specific gravity of 0.8. The span is about 96 inches of water column plus any extra space your pipes make. Then pick the range code that puts a margin around that value. It is harder to make a mistake when the span is set too close to the sensor's low range. Check the current Yokogawa datasheet for the exact range codes. That's the only document that tells you what you can order.

Accuracy, Stability, and Speed

If you look at the product information, it says that the reference accuracy for differential pressure is ±0.055% and for static pressure it is ±0.5%. Over 10 years, long-term stability is ±0.1% of URL, and overpressure is ±0.03% of URL. For differential pressure, the response time is 90 ms, and for steady pressure, it's 360 ms. Based on the DPharp single-crystal silicon resonance sensor, these numbers are correct. One thing to remember is that they only talk about the transmitter and not the whole loop. On top of that, density drift, leg errors, and impulse line problems make things even less certain. During regular use, the Back-Check self-diagnosis method also checks the quality of the measurements.

Output Signal, Materials, and Safety Certification

The Yokogawa EJA110E can measure, show, or remotely keep an eye on static pressure and change difference pressure into a 4–20 mA DC output. With remote setting, workers can change factors without having to go to the site. The product information talks about a four-bolt design that holds pressure, flange seals made of 316L stainless steel and Teflon, and double sealing that meets ANSI/ISA 12.27.01 standards. Tests by TÜV Rheinland and EXIDA confirmed that it works well; single units meet SIL2 standards, and redundant setups meet SIL3 standards. The model code determines the process connections, wet materials, approvals, and temperature limits. Before you order, make sure you read the installation and operation manual to find out more.

Configuring the EJA110E and Avoiding Common Errors

Define the Tank and Calculate the Span

A written process definition is the first step in good configuration. I need to know the height of the tank, the lowest and highest levels, the pressure inside the vessel, the density of the liquid, its temperature, how corrosive it is, how thick it is, how accurate it needs to be, what signal it needs to send, and what certifications it needs. Then figure out the pressure span, which is density times level change, with any wet-leg pressure taken into account. Check that against the range of sensors you want to buy. An example of a wet leg is when the high-pressure tap is at the bottom, and the low-pressure tap is above the highest level. This means that the differential pressure at the empty level is generally negative. In that case, plan a lower range number that is negative.

Set Up, Commission, and Validate

Next, mount the Yokogawa EJA110E high-performance differential pressure transmitter and connect the high side to the lower tap. Then, connect the low side to the vapor tap and check the impulse lines for leaks. Then, put in zero and span in engineering units, set damping to stop the surface from moving, and pick the failure mode that your control system is expecting. Check the scaling in the DCS or PLC with the 4–20 mA output. Look at the reading through a sight glass or dip the tool by hand at least twice. Write down the final data on setup and calibration for the repair team. Setting from a distance saves trips to the field for fine-tuning.

Common Problems and Fixes

Most obvious transmitter problems are caused by problems with the placement or the process. A reversed signal is made when the high and low lines are switched around. If you enter the wrong wet-leg height, the change will always be zero. The level number moves around because the density changes when the temperature or concentration changes. When lines get clogged, leak, gas gets trapped, condensation forms, or it freezes, readings become slow, noisy, or stuck. If you need it, I recommend sloped impulse lines, drain and vent valves, and freeze protection. Another thing to check is the static pressure reading. The transmitter can show it, and you can compare it to the tank pressure gauge. A difference means there is a problem with the pipes, not the sensor.

Comparing the EJA110E With Other Options for Closed Tanks

EJA110E, EJA120E, Rosemount 3051, and Siemens DP Transmitters

Don't compare transmitters by brand name, but by application data. The Yokogawa EJA120E is known for having a high turndown, compensating for static pressure effects, and staying stable at low and high temperatures. Level work can also be done with the Rosemount 3051 and the Siemens DP transmitters. Put each candidate in order based on their range, accuracy, ability to handle static pressure, contact options, approvals, process links, diagnostics, availability, and service support. Since we sell Yokogawa, Emerson Rosemount, and Siemens products, I can look at datasheets from all three brands and not favor one over the other. The 100:1 range ratio and ±0.055% reference accuracy of the yokogawa EJA110E high-performance differential pressure transmitter make it a good choice for many closed-tank jobs.

DP Transmitter vs. Absolute Pressure Transmitter

An absolute pressure transmitter checks its readings against a vacuum. It reads the liquid level plus the pressure in the vessel. When the tank pressure changes, this sum hides the level signal. It would cost more and be more likely to be wrong if you used a second instrument to measure vapor pressure and then did the math to subtract it. Because it takes the difference between the two pressures at the sensor, a DP transmitter is the best choice for closed-tank level. Absolute transmitters can still be used for process estimates, tracking vacuums, and showing vessel pressures. As an extra variable, the transmitter also reports static pressure, so you get a second reading from the same thing.

Matching the Transmitter to Your Tank and Fluid

The final choice is based on the properties of the fluid. Direct impulse piping works best with clean, non-viscous liquids. Fluids that are thick, corrosive, or crystallizing can block impulse lines. In these situations, diaphragm seals may be needed. In the EJA series, Yokogawa has different diaphragm-seal DP models, so make sure you know which model you want before you place your order. Services with changing densities, multiple phases, or high or low temperatures should be reviewed by engineers. Also think about the total cost of ownership, which includes building, tools, setup, calibration, spare parts, delivery, and support. The wide range ratio cuts down on stocking needs and makes upkeep easier, which is helpful when one model is used for multiple tanks.

Buying a Yokogawa EJA110E: RFQ Details and Verification Checklist

What to Include in Your RFQ

Without a full request, there will be delays. Send the model or configuration code, along with the range you need, the tank's size, the density of the liquid, the process pressure, the temperature, the process connection, the diaphragm material, the output signal, approvals, the number, the location, and the date you need it delivered. Our team will come up with an example code for you to look over if you don't have one already. Details like leg type and how corrosive the fluid is are just as important as the pressure range because they determine the materials and parts that can be used. A short, clear RFQ also speeds up the quote process because there is less questioning back and forth.

Questions to Ask Your Supplier

Price doesn't tell you much by itself. It is important to find out if the unit is the original one, if the seller is an official Yokogawa distributor, and if you get serial tracking, documentation, and calibration certificates. Ask about guarantee terms, stock levels, shipping times, and customer service after the sale. Accessories, calibration, or technical help may not be included in the cheapest quote. Items that are missing can cause mistakes in the configuration or cause the project to be delayed. One company that is allowed to sell Yokogawa products is Shaanxi Honglixing Electronic Technology Co., Ltd. (HLX). We sell original goods that come with warranties from the manufacturers. Our expert and after-sales teams have more than ten years of experience in the field.

Pre-Installation Verification Checklist

Check the Yokogawa EJA110E high-performance differential pressure transmitter model, range code, output signal, approvals, wetted materials, pressure rating, and temperature limits against the tank fluid before installing it. On the mechanical side, check the high- and low-side connections, the arrangement of the manifold, the support and slope of the impulse line, the drainage and venting, and the leak tightness. In terms of electricity, you should check the loop power, polarity, grounding, warning, failure behavior, DCS or PLC scale, and engineering units. During this review, keep the most recent installation and operation instructions open. Also, keep the final setup and calibration records for future use. Before approval, this process finds most of the mistakes.

Conclusion

When engineers use the yokogawa EJA110E high-performance differential pressure transmitter as a differential pressure level system, it can find the level of liquid in closed tanks. The side with high pressure measures the liquid head at the bottom, and the side with low pressure measures the vapor pressure above it. This means that the vessel pressure is zero. For accurate results, you need to know the density of the liquid, choose the right wet-leg or dry-leg, and use real tank data to figure out the span. The transmitter has a standard accuracy of ±0.055%, a range ratio of 100:1, a reaction time of 90 ms, and an output range of 4–20 mA. Loop performance is set by the quality of the installation. Most problems, like connections that are backward, shifts in density, and impulse lines that get plugged, are caused by the way the sensor was set up. Fluids that block impulse lines or have different densities need to be looked at by engineers, and a correct purchase is supported by a full RFQ with verified documentation.

FAQ

1. Can the EJA110E check the level of a tank that is under pressure?

Yes. Set it up as a DP system, with the low side at the gas space and the high side at the lower tap. The pressure in the tank goes away, and you should first check the density of the liquid.

2. Is it a level transmitter or a pressure transmitter?

It is a sensor for differential pressure. Using the density of the liquid, your control system turns the pressure into a level.

3. What kind of output signal does it give off?

It sends a 4–20 mA DC signal and can show or check static pressure from a distance. Check the model code for digital options.

4. How do I pick the measurement range?

You can find the range code that fits that span by multiplying the density by the level change and then adjusting for wet-leg pressure.

Request a Yokogawa EJA110E High-Performance Differential Pressure Transmitter Quote From HLX

HLX can be reached at sales01@hlx8.com with your tank height, vessel pressure, liquid density, temperature, and output needs. As a supplier of the yokogawa EJA110E high-performance differential pressure transmitter, we offer original products, fast delivery, a configuration review, and support from experienced engineers after the sale that is backed by a warranty. 

References

1. Instrument Engineers' Handbook, Volume 1: Process Measurement and Analysis, 2003

2. Fundamentals of Industrial Instrumentation and Process Control, 2005

3. Perry's Chemical Engineers' Handbook, 2019

4. IEC 61508 Functional Safety of Electrical/Electronic/Programmable Electronic Safety-Related Systems, 2010

5. IEC 61511 Functional Safety – Safety Instrumented Systems for the Process Industry Sector, 2016

6. ISA-5.1 Instrumentation Symbols and Identification, 2022